DZS IMACS 200
PSI has integrated, sold and supported for many years. The IMACS has been discontinued. PSI highly recommends the AM3440 product line from Loop Telecom
TDM Intelligent Channel Bank with Built-in Cross Connect
Compact Integrated Multiple Access Communication Server
Overview
The concept of an integrated one box solution for advanced voice and data applications began with the introduction of the IMACS. The IMACS 200 carries on that tradition with an integrated solution optimized for smaller port size applications that the IMACS could not economically address. An array of the most popular interfaces and features from the IMACS has been bundled into a small 2U chassis providing the ultimate in ease of installation.
Reliable communications are vital to any organization. The IMACS 200 addresses this need while providing compact size, low cost, and a high level of voice and data integration. This makes it an ideal choice for providing a variety of services to small end points and remote locations in any modern telecommunications network.
Optimized for the unique needs of electric utilities, the IMACS 200 system supports a wide range of specialty traffic, including teleprotection (EIA-232 and IEEE C37.94 optical interface to protection relays), SCADA, surveillance video, substation automation and alarms, radio, Ethernet and telephony.
The DZS IMACS 200 system offers a powerful array of integrated network diagnostic and fault isolation capabilities. These include Bit Error Rate Testers, test tone and signaling state generation, digital and analog loop back-support, and remote configuration and control. IMACS 200 meets stringent standards criteria, such as IEEE 1613, RoHS, and CE, which means you can deploy it anywhere in your network.
Reference Guides: DZS IMACS 200 Reference
Specifications
|
Features
- Two Rack-Unit Design
- -48 Vdc, 125 Vdc, 120/220 Vac powering options
- Redundant Power Supplies (optional)
- Powerful System Maintenance, Diagnostic, and Fault Isolation Capabilities Including LEDs, Loop back, BERT, automatic diagnostics
External Alarm Monitoring
- Digital Non Blocking Cross Connect
- IEEE 1613 Certified – including temperature hardening
- RoHS Compliant
- IEEE C37.94 Optical interface to protection relays
- Multiple Voice and Data Access Interfaces
- Flexible Electrical and Optical T1/E1 WAN Options
|
Benefits
- Supports Voice, Data, Control, and Monitoring Interfaces in a Single Device
- Low Initial Cost
- Minimal Installation Cost
- Easy Installation in Tight Spaces
- Deployable in Harsh Environments
- Deployable Worldwide
- Simplified Maintenance with same “Look and Feel” as Existing IMACS Platform
- Compatible with existing IMACS OnLine EMS
- Optimized for electrical utility sub-station applications
- Optical interface option offers superior immunity from electrical noise and isolation from foreign voltages / signal ground loops
|
Dimensions
- 3.47 in. x 17.31 in. x 9.48 in.
8.8 cm x 44.0 cm x 24.1 cm
Weight
- Approximately 10 lbs. (4.54 kg) depending on configuration
Power
- -48 Vdc
- 125 Vdc
- 120/220 Vac
- Optional redundant power supplies
Interfaces
- 4 - T1/E1
- 4 - 4 Wire E&M/TO
- 4 – 2 Wire FXS (600 ohm)
- 2 – V.35 (n x DS0)
- 5 – RS-232 (2.4, 4.8, 19.2, 28.8 and 38.4 kbps)
- 4 – alarm inputs
- 4 – alarm outputs (dry contacts)
- 2 – IEEE C37.94 compliant serial data over fiber (optional)
- 1 – 10BaseT Ethernet
- 2 – Optical T1/E1 WAN, Single fiber, 8 Mbps (optional)
Standards Support
- IEEE 1613
- RoHS
- AT&T PUB 43801
- ITU-T G712
- TR62411
Voice Support
|
Protocol Support
- Ethernet IEEE 802.3
- RFC 1490 – Encapsulation
- ARP, RIP and OSPF Bridging and routing
- V.35
- RS 232
- IEEE C37.94
Management
- RS-232 Serial VT-100 port
- Ethernet Port
- Command Line Interface (Menu based)
- SNMP V2
- Telnet
Regulatory Compliance
Safety:
- United States - UL 60950-1
- Canada - CSA C2.22 No. 60950-1
- European Union - EN 60950-1
- International / CB Scheme - IEC 60950-1 3rd Edition
EMC:
- United States - FCC Part 15 Class A
- Canada - ICES-03
- European Union/CE Mark - ETSI EN 300 386:2001 which includes:
EN 55022 Class A EN 6100-4-2 EN 6100-4-3 EN 6100-4-4 EN 6100-4-5 EN 6100-4-6 EN 6100-3-2 - N/A for DC EN 6100-3-3 - N/A for DC
Operating Requirements
- Temperature –40°C to +70°C
- Humidity 95 % max, non-condensing
|
|
|